中文版
Home   About   News   Products   Contact
 
Products
 
Reflow Oven (1)
PCB Insertion Loss Measurement (2)
PCB Reliability Test (5)
Bentham Optical Measurement (12)
Compliance West Tester (14)
Resistance to Abnormal Heat and to Fire (0)
Joint finger and mechanism secure testing apparatus (0)
Waterproof and dust-proof testing apparatus (0)
IEC/UL electric secure testing apparatus (0)

Hipot Tester HT-3000P  
 

 

AC/DC Hipot/Continuity Tester for UL, CSA and TUV Production line testing

 

 

The HT-3000P is a production line AC/DC Hipot Tester. This tester can test to UL, CSA and other safety agency

production line requirement with either AC or DC voltage. An AC/DC hipot and ground continuity tester that is easy

to use and priced right. All the features you need but none of the ones that you pay for but use only once. Select

AC or DC output via front panel button. Simple for priduction line personnel, easy to set up.

 

Specifications

Voltage Test Type AC/DC
Voltage Range

0-2000 AC     0-2800 DC

Current Range

1-20 mA AC    1-5 mA DC

Input Voltage Requirements

117-127 V, 50/60 Hz

Fuse Requirements 120 V, 1.5A

Arc Detect

Separate High Frequency  circuit

Leakage Detect

Separate Low Frequency  circuit
Ground Continuity 3 ohm (Defeatable)
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy +/- 5%
HV Shutdown by Ground Fail < 7 mS
Duty Cycle 100%
Discharge Time

< 100 mS VAC

< 1 Sec VDC

Transformer Ouput < 500 VAC
Pass/Fail Repeatability +/- 3%
Output Connector NEMA Plug
Display 4 digits LED display
Test Indicator LED indicators
Failure Indicator LED indicators and buzzer
Programable No
PLC Interface Optional
TestLink Optional
TestMinder No
Voltage Hold on Failure No
Top Mounted Handle Optional
Test Defeat Ground Continuity
Autoreset on Pass Optional
Operation Temperature 15 - 40 ℃
Relative Humidity Range 0 - 90% Non-condensing
Dimensions W 9-1/4 x H 4-3/4 x D 10 (inch)
Weight 14 Lbs

 

 

Features

 

  • Adds high precision leakage current and duration settings to the user-friendly HT-3000 for better control of tests. Allows no load setup of leakage current and test dwell times. Once entered, leakage current and test dwell times can be referenced on the front panel display at any time. Leakage currents can be set from 1-20 mA AC or 1-5mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
    Small and light. 9.25" wide x 4.25" high x 10" deep. 11 lbs . But rugged enough to test manufactured housing.
    Ground continuity check is defeatable for testing two-wire products.
    Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
    J2 and J3 cords allow connection of pigtail power leads.
    Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
    Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
    Operation Instructions are printed on the rear panel for easy reference.
    In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
    RED lights and a buzzer leave no question if a failure has occurred.
    Expandable for TUV/European Agency Testing. Can be connected to our GF -30ac 25A Ground Bond Tester with optional TEST-LINK™.
    Optional 120kohm calibration resistor can be mounted on the rear panel.
  • Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1.

 

 
       
 

 

Asia Qtech Instrument Inc
4F-B, No 327, Sec. 1, Tiding Blvd., Neihu District, Taipei, Taiwan
Tel:+886-2-27966289 Fax:+886-2-27956098