中文版
Home   About   News   Products   Contact
 
Products
 
Reflow Oven (1)
PCB Insertion Loss Measurement (2)
PCB Reliability Test (5)
Bentham Optical Measurement (12)
Compliance West Tester (14)
Resistance to Abnormal Heat and to Fire (0)
Joint finger and mechanism secure testing apparatus (0)
Waterproof and dust-proof testing apparatus (0)
IEC/UL electric secure testing apparatus (0)

Hipot Tester HT-5000P  
 

 

HT-5000P: AC/DC Output

 

 

The HT-5000P is best suited for engineers conducting type testing and product design. Front panel voltage

dial-up and AC/DC rocker switch make this unit easy to use.

 

A 5000V AC hipot tester that is easy to use and priced right. All the features you need but none of the ones

hat you pay for but use only once. Select AC or DC output via front panel button. Simple for production line

personnel, easy to set up.

 

When a problem is found, the operator can defeat the leakage current limit and dielectric breakdown shutoffs

to allow troubleshooting and analysis of problems with the DUT.

 

The HT-5000P includes precision leakage current and test time setup and viewing from the LED meter.

Adjustment is made with no HV output.

 

 

Specifications

Voltage Test Type AC/DC 
Voltage Range 0-5000 AC   0-6000 DC
Current Range 1-010 mA Ac   1-5 m A DC
Input Voltage Requirements

117-127V, 50/60Hz   120V, 1.5A 

Fuse Requirements See Rear Panel for correct rating

Arc Detect

Separate Low Frequency circuit
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy +/- 2%
Duty Cycle 100%
Discharge Time (Resistive Load) Factory Set 8 Sec max
Transformer Ouput <500 VAC
Pass/Fail Repeatability +/- 3%
Output Connector High Voltage Jack
Display 4 digits LED display
Test Indicator LED indicators
Failure Indicator LED indicators and buzzer
Programable No
PLC Interface Optional
TestLink No
TestMinder No
Voltage Hold on failure Available
Top Mounted Handle Optional
Test Defeat

- Ramp Time

- Test Time

- Breakdown Detect

Autoreset on Pass Optional
Operation Temperature

15 - 40 ℃

Relative Humidity Range 0 - 90% Non-condensing
Dimensions W 10 x H 5 x D 12 (inch)
Weight 17.5 Lbs

 

Features

  • High precision leakage current and duration settings. Allows no load setup of leakage current and test dwell times. Once entered, leakage current and test dwell times can be referenced on the front panel display at any time. Leakage currents can be set from 1-10 mA AC or 1-5mA DC in 0.1mA increments. Dwell times can be set from 1-60 seconds in 1 second increments. Small and light. 11.25" wide x 4.75" high x 11" deep. 16 lbs. Leakage current and dielectric breakdown shutdowns can be defeated to allow troubleshooting of problems. Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance. Operation Instructions are printed on the rear panel for easy reference.
  • In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
    RED lights and a buzzer leave no question if a failure has occurred.

 

 
       
 

 

Asia Qtech Instrument Inc
4F-B, No 327, Sec. 1, Tiding Blvd., Neihu District, Taipei, Taiwan
Tel:+886-2-27966289 Fax:+886-2-27956098