中文版
Home   About   News   Products   Contact
 
Products
 
Reflow Oven (1)
PCB Insertion Loss Measurement (2)
PCB Reliability Test (5)
Bentham Optical Measurement (12)
Compliance West Tester (14)
Resistance to Abnormal Heat and to Fire (0)
Joint finger and mechanism secure testing apparatus (0)
Waterproof and dust-proof testing apparatus (0)
IEC/UL electric secure testing apparatus (0)

Hipot Tester HT-10000P AC/DC  
 


HT-10000P AC/DC series provide up to 10000

 

 

For use in production line testing of high voltage systems, components, product design and type testing.

 

The dielectric withstand test is a test which is recognized by safety agencies worldwide as a valid criterion of safe assembly

of end-use equipment. The HT-10000P is designed as a research instrument to determine the dielectric properties of component

assemblies of end-use equipment. It applies a high-voltage potential between Output and Return test leads and monitors

Leakage Current and watches for Dielectric Breakdown during the test. To aid in testing, the HT-10000P can be configured

with or without voltage ramp time, with or without a test duration timer, and can be set to deliver high voltage after an arc has

been detected to pinpoint an area of arcing.

  • Front panel voltage dial makes this unit easy to use.
  • Auto-ramp on low current models. Current limit and test time settings on front panel.
  • A variety of safety and convenience options are available.
  • Provided with leads, manual, and calibration certificate.

 

Specifications

HT-10000P AC/DC

Voltage Test Type AC/DC 
Voltage Range 0-10000 VAC   0-14000 VDC
Current Range 3 mA at 10 KVAC   1 mA at 14 KVDC
Input Voltage Requirements

108-132V, 50/60Hz   2A max

Fuse Requirements 120 VAC

Arc Detect

Separate High Frequency circuit

Leakage Detect

Separate Low Frequency circuit
Ground Continuity N/A
Ground Continuity Current N/A
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy +/- 2%
Current Meter Accuracy +/- 0.1 mA
Resistance Measure Range N/A
Resiatance Auto Offset Range N/A
Resistance Measure Accuracy N/A
HV Shutdown by Ground Fail N/A
Duty Cycle 100%
Transformer Ouput < 500 VAC
Pass/Fail Repeatability +/- 3%
Output Connector High Voltage Jack
Display 4 digits LED display
Test Indicator LED indicators
Failure Indicator LED indicators and buzzer
Programable No
PLC Interface No
TestLink N/A
TestMinder No
Voltage Hold on failure Available
Top Mounted Handle No
Test Defeat Ramp Time, Test Time and Breakdown Fail
Autoreset on Pass Optional
Operation Temperature 15 - 40 ℃
Relative Humidity Range 0 - 90% Non-condensing
Dimensions W 17 x H 5 x D 16.75 (inch)
Weight 32 Lbs

HT-10000P AC

Voltage Test Type AC
Voltage Range 0-10000 VAC
Current Range 8 mA
Input Voltage Requirements

108-132V, 50/60Hz   2A max

Fuse Requirements 120 VAC

Arc Detect

Separate High Frequency circuit

Leakage Detect

Separate Low Frequency circuit
Ground Continuity N/A
Ground Continuity Current N/A
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy +/- 2%
Current Meter Accuracy +/- 0.1 mA
Resistance Measure Range N/A
Resiatance Auto Offset Range N/A
Resistance Measure Accuracy N/A
HV Shutdown by Ground Fail N/A
Duty Cycle 100%
Transformer Ouput < 500 VAC
Pass/Fail Repeatability +/- 3%
Output Connector High Voltage Jack
Display 4 digits LED display
Test Indicator LED indicators
Failure Indicator LED indicators and buzzer
Programable No
PLC Interface No
TestLink N/A
TestMinder No
Voltage Hold on failure Available
Top Mounted Handle No
Test Defeat Ramp Time, Test Time and Breakdown Fail
Autoreset on Pass Optional
Operation Temperature 15 - 40 ℃
Relative Humidity Range 0 - 90% Non-condensing
Dimensions W 10 x H 5 x D 12 (inch)
Weight 17.5 Lbs

HT-10000P DC

Voltage Test Type DC 
Voltage Range 0-10000 VAC   0-14000 VDC
Current Range 3 mA at 10 KVAC   1 mA at 14 KVDC
Input Voltage Requirements

108-132V, 50/60Hz   2A max

Fuse Requirements 120 VAC

Arc Detect

Separate High Frequency circuit

Leakage Detect

Separate Low Frequency circuit
Ground Continuity N/A
Ground Continuity Current N/A
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy +/- 2%
Current Meter Accuracy +/- 0.1 mA
Resistance Measure Range N/A
Resiatance Auto Offset Range N/A
Resistance Measure Accuracy N/A
HV Shutdown by Ground Fail N/A
Duty Cycle 100%
Transformer Ouput < 500 VAC
Pass/Fail Repeatability +/- 3%
Output Connector High Voltage Jack
Display 4 digits LED display
Test Indicator LED indicators
Failure Indicator LED indicators and buzzer
Programable No
PLC Interface No
TestLink N/A
TestMinder No
Voltage Hold on failure Available
Top Mounted Handle No
Test Defeat Ramp Time, Test Time and Breakdown Fail
Autoreset on Pass Optional
Operation Temperature 15 - 40 ℃
Relative Humidity Range 0 - 90% Non-condensing
Dimensions W 10 x H 5 x D 12 (inch)
Weight 17.5 Lbs

 

Features

  • HT10000P AC: AC output to 10000 Volts. Delivers 1 through 8 milliamps. Custom outputs to 25 mA.
  • HT10000P DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments; leakage limit, ramp time, test time and voltage.
  • Ergonomic design for safety and ease of use.
  • High voltage output jack.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High efficiency design, low power consumption.
  • All test leads included.
  • Calibrated to NIST standards.
  • 1 year warranty HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible

 

 
       
 

 